phone Phone
+628161105088
menu

CV. Kalindra Mitra Niaga

sql
Multifunction Simulator EC 10 & EC 25 SIKA
Hover to Zoom

Jual Multifunction Simulator EC 10 & EC 25 SIKA



Spesifikasi Multifunction Simulator EC 10 & EC 25 SIKA

 Alat Ukur Kalibrasi Temperature Simulator & Measurement

             Type

        EC 10

        EC 25

   Resistance thermometer (RTD)

 RTD signal generation and     measurement

 Pt100, Pt200, Pt500, Pt1000, Cu10,

 Cu50

  Ω-generator function

   0...4000 Ω

   0...40 000 Ω

  Ω-measurement function

   0...5500 Ω

   0...5500 Ω

  Accuracy (rdg. + const.)

   ±0.05 %

  Selectable temperature unit

   °C / °F

  Measurement of

  multi-wire connections

    2 / 3 / 4

     2 / 3

  Thermocouples (TC)

 TC signal generation and     measurement

   J, K, T, R, S,

   B, N, E, U, L

J, K, T, R, S, B, N, E

  mV generator function

   -100...1100 mV

   -100...110 mV

  mV measurement function

   -50...550 mV

  Accuracy (rdg. + const.)

   ±0.02 %

  Selectable temperature unit

   °C / °F

   Internal comparison point

   ±0.5 °C

Current (mA)

Loop current signal generation

 

   0...22 mA

  Loop current signal     measurement

 

   -5...55 mA

   Accuracy (of rdg. + const.)

 

   ±0.02 %

   Current loop supply

 

24 V ±10 %, 22 mA

   Voltage (V)

   Voltage signal generation

 

   -1...11 V

   Voltage signal measurement

 

   -5...55 V

   Accuracy (of rdg. + const.)

 

   ±0.02 %

   Continuity (O / C)

   Continuity measurement

   O / C

   Switching threshold "open"

   0.5 kΩ

   Frequency and pulse (Hz)

   Frequency and pulse signal    generation

 

   3 Hz...110 kHz

   Frequency and pulse signal    measurement

 

   3 Hz...50 kHz

   Accuracy (of rdg. + const.)

 

   ±0.005 %

 

   Functions

      EC 10

                EC 25

   Generation

   High-speed call values

 

7 points (fix) in 25 % steps

   Linear steps and ramps

 

          √

   Output zero

          √

          √

   Transmitter function simulation

 

          √

   Measurement

   Measured value hold function

         √

          √

   Averaging function

         √

          √

   Room temperature display

          √

          √

 

EC 10

Operator guidance Keypad

Battery supply / Operating time Approx. 25 h with Auto-Power off

 

EC 25

Operator guidance Keypad

Separate channels for parallel signal processing

Battery supply / Operating time Approx. 20 h with Auto-Power off

Untuk keterangan lebih lanjut, silahkan download PDF ini :

phoneHubungi Kami